Table 2

Thermal and energy specifications for test houses.

CONVENTIONAL HOUSE
Embedded Image
SOLAR HOUSE
Embedded Image
FLOOR AREA:1502 sq. ft1500 sq. ft
WINDOW AREA:
   South50 sq. ft144 sq. ft
   East1520
   West4333
   North9964
WINDOW/WALL SHADE COEFFICIENT:
   South.68 sum, .40 wi.20 sum, .90 win
   East1.0 sum/win.30 sum, 1.0 win
   West1.0 sum/wint.30 sum, 1.0 win
   North.89 sum/win1.0 sum/win
WALL AREA (NET):
   South377 sq. ft398 sq. ft.
   East324400
   West258387
   North263514
INSULATION:
   Roof/CeilingR-21 (1516 sq. ft.)R-31 (1224 sq. ft.)
   WallsR-I2.5R-21
   Slab PerimeterR-1.0 (176 1. ft.)R-1.0 (146 1. ft.)
   WindowsR-0.9R-4 (south only)
EQUIVALENT THERMAL MASS:
   Sunlit Slab0 sq. ft., 0 lbs195 sq. ft., 9100 lbs
   Shaded Slab126 sq. ft., 5880 lbs.551 sq. ft., 25700 lbs.
   Carpeted Slab1376 sq. ft., 64200 lbs.483 sq. ft., 22500 lbs.
   Fireplace56 sq. ft., 1680 lb-----
INFILTRATION RATE:0.75 air changes/hour0.60 air changes/hour
VENTILATION RATE:8 air changes/hour10 air changes/hour
GAS FURNACE EFFICIENCY:.70.70
AIRCONDITIONER EFFICIENCY:EER = 8EER = 8
THERMOSTAT SETTINGS:68°F low, 78°F high68°F low, 78°F high
CONVENTIONAL D.H.W. EFFICIENCY:.70.70
SOLAR D.H.W. COLLECTOR AREA:-----44 sq. ft
HOT WATER USAGE:18 gal/person/day18 gal/person/day
OCCUPANTS:44
ENERGY COSTS:
   Natural Gas (Heating & DHW)$0.471/Therm$0.471/Therm
   Electricity (Cooling)$0.07/kwh$0.07/kwh